Types
/software/ofed/component_ofed_openib_options
- Description: openib options
/software/ofed/component_ofed_openib_options/onboot
- Description: Start HCA driver upon boot
- Optional
- Type: boolean
- Default value: true
/software/ofed/component_ofed_openib_options/renice_ib_mad
- Description: MAD datagrams thread priority
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_options/set_ipoib_cm
- Description: disable CM for IPoIB for large clusters
- Optional
- Type: boolean
- Default value: true
/software/ofed/component_ofed_openib_options/set_ipoib_channels
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_options/ipoib_mtu
- Description: IPoIB MTU setting for CM
- Optional
- Type: long
- Range: 0..65536
/software/ofed/component_ofed_openib_options/srpha_enable
- Description: SRP High Availability
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_options/srp_daemon_enable
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_options/run_sysctl
- Description: sysctl tuning
- Optional
- Type: boolean
- Default value: true
/software/ofed/component_ofed_openib_options/run_affinity_tuner
- Description: affinity tuning
- Optional
- Type: boolean
- Default value: true
/software/ofed/component_ofed_openib_options/run_mlnx_tune
- Description: Enable MLNX autotuning
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_options/node_desc
- Description: node description
- Optional
- Type: string
/software/ofed/component_ofed_openib_options/node_desc_update_timeout
- Description: Max time in seconds to wait for node's hostname to be set
- Optional
- Type: long
- Range: 0..
- Default value: 120
/software/ofed/component_ofed_openib_options/node_desc_time_before_update
- Description: Wait (in sec) before node description update
- Optional
- Type: long
- Range: 0..
- Default value: 10
/software/ofed/component_ofed_openib_options/post_start_delay
- Description: Seconds to sleep after openibd start finished and before releasing the shell
- Optional
- Type: long
- Range: 0..
- Default value: 0
/software/ofed/component_ofed_openib_options/cx3_eth_only
- Description: ConnectX-3 ethernet only
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_modules
- Description: openib modules to load
/software/ofed/component_ofed_openib_modules/ucm
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_modules/umad
- Optional
- Type: boolean
- Default value: true
/software/ofed/component_ofed_openib_modules/uverbs
- Optional
- Type: boolean
- Default value: true
/software/ofed/component_ofed_openib_modules/rdma_cm
- Description: RDMA CM (connected mode) mode
- Optional
- Type: boolean
- Default value: true
/software/ofed/component_ofed_openib_modules/rdma_ucm
- Description: RDMA UD (unreliable datagram) mode
- Optional
- Type: boolean
- Default value: true
/software/ofed/component_ofed_openib_modules/ipoib
- Description: IPoIB
- Optional
- Type: boolean
- Default value: true
/software/ofed/component_ofed_openib_modules/e_ipoib
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_modules/sdp
- Description: SDP (Socket Direct Protocol)
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_modules/srp
- Description: SRP SCSI RDMA Protocol
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_modules/srpt
- Description: SRP Target
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_modules/rds
- Description: Reliable datagram socket
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_modules/iser
- Description: ISCSI RDMA
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_modules/mlx4_vnic
- Description: Mellanox ConnectX-3 Virtual NICs
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_modules/mlx4_fc
- Description: Mellanox ConnectX-3 FibreChannel over Ethernet
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_modules/mlx4_en
- Description: Mellanox ConnectX-3 Ethernet
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_hardware
- Description: openib hardware modules to load
/software/ofed/component_ofed_openib_hardware/mthca
- Description: Mellanox Inifinihost III
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_hardware/mlx4
- Description: Mellanox ConnectX-2/3
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_hardware/mlx5
- Description: Mellanox ConnectX-4/5 / ConnectIB
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_hardware/mlx_en
- Description: Mellanox ethernet-only
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_hardware/ipath
- Description: Legacy Qlogic IB
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_hardware/qib
- Description: Qlogic/Intel TrueScale IB
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_hardware/qlgc_vnic
- Description: Qlogic ethernet
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_hardware/cxgb3
- Description: Chelsio T3/T4
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_hardware/cxgb4
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib_hardware/nes
- Description: NetEffect
- Optional
- Type: boolean
- Default value: false
/software/ofed/component_ofed_openib
- Description: openib configuration
/software/ofed/component_ofed_openib/config
- Description: location of openibd config file
- Optional
- Type: string
- Default value: /etc/infiniband/openib.conf
/software/ofed/component_ofed_openib/options
- Optional
- Type: component_ofed_openib_options
/software/ofed/component_ofed_openib/modules
- Optional
- Type: component_ofed_openib_modules
/software/ofed/component_ofed_openib/hardware
- Optional
- Type: component_ofed_openib_hardware
/software/ofed/component_ofed_partition_property
/software/ofed/component_ofed_partition_property/guid
- Description: Port GUID
- Optional
- Type: string
/software/ofed/component_ofed_partition_property/membership
- Optional
- Type: string
-
/software/ofed/component_ofed_partition
-
Description: Partition entry
-
/software/ofed/component_ofed_partition/key
- Description: partition key (aka PKey); default is 32767/0x7fff. (partition keys are unique; first name is used by OpenSM for same keys)
- Optional
- Type: long
- Range: 0..32767
- Default value: 32767
/software/ofed/component_ofed_partition/ipoib
- Description: support IPoiB in this partition
- Optional
- Type: boolean
/software/ofed/component_ofed_partition/rate
- Description: Rate: e.g. 3 (10Gbps), 4 (20Gbps),...
- Optional
- Type: long
- Range: 0..8
/software/ofed/component_ofed_partition/mtu
- Description: MTU: e.g. 4 (2048 bytes), 5 (4096 bytes)
- Optional
- Type: long
- Range: 0..5
/software/ofed/component_ofed_partition/properties
- Description: Partition properties
- Optional
- Type: component_ofed_partition_property
/software/ofed/component_ofed_opensm
- Description: Subnet manager configuration
/software/ofed/component_ofed_opensm/daemons
- Description: daemons to restart on configuration changes
- Optional
- Type: string
/software/ofed/component_ofed_opensm/partitions
- Description: SM partitions configuration. Dict key is the partition name
- Optional
- Type: component_ofed_partition
/software/ofed/component_ofed_opensm/names
- Description: Node name map configuration. Dict key is the GUID starting with 'x' (the 0 is prefixed automatically)
- Optional
- Type: string
/software/ofed/ofed_component
/software/ofed/ofed_component/openib
- Optional
- Type: component_ofed_openib
/software/ofed/ofed_component/opensm
- Optional
- Type: component_ofed_opensm
-